Limit your search
- CAT Scan, X Ray14
- CAT Scan, X-Ray14
- CT Scan, X-Ray[remove]14
- CT X Ray14
- Cine-CT14
- more Keywords»
Search
You searched for:
Keyword
CT Scan, X-Ray
Remove constraint Keyword: CT Scan, X-Ray
Publisher
i-Human Patients, Inc., Inc.
Remove constraint Publisher: i-Human Patients, Inc., Inc.
Subject
Multimodal Imaging
Remove constraint Subject: Multimodal Imaging
« Previous |
1 - 10 of 14
|
Next »
Number of results to display per page
Search Results
- Title:
- CT (brain), Subarachnoid Hemorrhage, Frontal Parietal Temporal Cortex, Sylvian Fissure
- Description:
- 4th ventricle tent Cerebelli Frontal parietal temporal cortex Sylvian fissure
- Keyword:
- Tomography, X-Ray Computer Assisted, Electron Beam Tomography, Computerized Tomography, X-Ray, Tomography, Transmission Computed, Diagnosis, CT Scan, X-Ray, Computerized Tomography, X Ray, Tomography, Xray Computed, CAT Scan, X Ray, Tomodensitometry, Hemorrhage, Subarachnoid, Subarachnoid Hemorrhage, Intracranial, X-Ray Computerized Axial Tomography, X-Ray Computer Assisted Tomography, Perinatal Subarachnoid Hemorrhage, Subarachnoid Hemorrhage, Aneurysmal, Tomography, X Ray Computed, Tomography, X-Ray Computerized Axial, Tomography, X-Ray Computerized, X Ray Computerized Tomography, Computed Tomography, X-Ray, Subarachnoid Hemorrhage, Spontaneous, SAH (Subarachnoid Hemorrhage), Cine-CT, X Ray Tomography, Computed, Computed X Ray Tomography, CT X Ray, X-Ray Tomography, Computed, CAT Scan, X-Ray, Electron Beam Computed Tomography
- Subject:
- Diagnostic Techniques and Procedures, Diagnostic Imaging, Pathological Conditions, Signs and Symptoms, Hemorrhage, Intracranial Hemorrhages, Pathologic Processes, Multimodal Imaging, Tomography, X-Ray Computed, Subarachnoid Hemorrhage
- Creator:
- i-Human Patients
- Publisher:
- i-Human Patients, Inc., Inc.
- Language:
- English
- Copyright Holder:
- i-Human Patients, Inc.
- Rights:
- http://www.i-human.com/service-agreement-print
- Resource Type:
- Medical Imaging
- Identifier:
- 1508
- Title:
- CT (brain), Subarachnoid Hemorrhage, Frontal parietal Temporal Cortex, Sylvian Fissure
- Description:
- 4th ventricle tent Cerebelli Frontal parietal temporal cortex Sylvian fissure
- Keyword:
- Computed Tomography, X-Ray, CT X Ray, Hemorrhage, Subarachnoid, Tomography, Transmission Computed, Electron Beam Tomography, Computed X Ray Tomography, Computerized Tomography, X Ray, Diagnosis, Subarachnoid Hemorrhage, Intracranial, X-Ray Computerized Axial Tomography, Tomography, X Ray Computed, Tomography, X-Ray Computerized, CAT Scan, X Ray, X Ray Computerized Tomography, Cine-CT, Perinatal Subarachnoid Hemorrhage, CT Scan, X-Ray, Electron Beam Computed Tomography, X Ray Tomography, Computed, Tomography, X-Ray Computer Assisted, Subarachnoid Hemorrhage, Aneurysmal, Tomography, Xray Computed, X-Ray Tomography, Computed, Computerized Tomography, X-Ray, Subarachnoid Hemorrhage, Spontaneous, Tomodensitometry, SAH (Subarachnoid Hemorrhage), CAT Scan, X-Ray, Tomography, X-Ray Computerized Axial, X-Ray Computer Assisted Tomography
- Subject:
- Pathological Conditions, Signs and Symptoms, Tomography, X-Ray Computed, Hemorrhage, Multimodal Imaging, Diagnostic Techniques and Procedures, Pathologic Processes, Subarachnoid Hemorrhage, Intracranial Hemorrhages, Diagnostic Imaging
- Creator:
- i-Human Patients
- Publisher:
- i-Human Patients, Inc., Inc.
- Language:
- English
- Copyright Holder:
- i-Human Patients, Inc.
- Rights:
- http://www.i-human.com/service-agreement-print
- Resource Type:
- Medical Imaging
- Identifier:
- 1508
- Title:
- CT (brain), Subarachnoid Hemorrhage, Frontal Parietal Temporal Cortex, Sylvian Fissure
- Description:
- 4th ventricle tent Cerebelli Frontal parietal temporal cortex Sylvian fissure
- Keyword:
- X Ray Computerized Tomography, Tomography, Transmission Computed, Cine-CT, Hemorrhage, Subarachnoid, Perinatal Subarachnoid Hemorrhage, Computed Tomography, X-Ray, CAT Scan, X-Ray, X-Ray Computerized Axial Tomography, X-Ray Computer Assisted Tomography, CT Scan, X-Ray, SAH (Subarachnoid Hemorrhage), Tomography, X Ray Computed, X-Ray Tomography, Computed, Tomography, X-Ray Computer Assisted, Computerized Tomography, X Ray, Subarachnoid Hemorrhage, Intracranial, Tomography, X-Ray Computerized Axial, Subarachnoid Hemorrhage, Spontaneous, CT X Ray, Electron Beam Tomography, CAT Scan, X Ray, Subarachnoid Hemorrhage, Aneurysmal, Computed X Ray Tomography, Tomodensitometry, Tomography, Xray Computed, Computerized Tomography, X-Ray, Tomography, X-Ray Computerized, Electron Beam Computed Tomography, Diagnosis, X Ray Tomography, Computed
- Subject:
- Intracranial Hemorrhages, Multimodal Imaging, Subarachnoid Hemorrhage, Pathological Conditions, Signs and Symptoms, Tomography, X-Ray Computed, Diagnostic Techniques and Procedures, Pathologic Processes, Hemorrhage, Diagnostic Imaging
- Creator:
- i-Human Patients
- Publisher:
- i-Human Patients, Inc., Inc.
- Language:
- English
- Copyright Holder:
- i-Human Patients, Inc.
- Rights:
- http://www.i-human.com/service-agreement-print
- Resource Type:
- Medical Imaging
- Identifier:
- 1508
- Title:
- CT (chest), Pulmonary Embolism with Infarction, Anterior to Posterior
- Description:
- CT Chest - Pulmonary embolism with infarct - anterior to posterior
- Keyword:
- Cine-CT, Tomography, X Ray Computed, Pulmonary Thromboembolism, X Ray Computerized Tomography, Pulmonary Embolisms, Tomography, X-Ray Computerized Axial, Tomography, X-Ray Computer Assisted, Electron Beam Tomography, Infarct, Computed X Ray Tomography, X Ray Tomography, Computed, Tomography, Transmission Computed, CT Scan, X-Ray, Computerized Tomography, X Ray, CAT Scan, X Ray, CAT Scan, X-Ray, Embolisms, Pulmonary, Electron Beam Computed Tomography, Thromboembolisms, Pulmonary, Diagnosis, Computerized Tomography, X-Ray, Tomography, X-Ray Computerized, X-Ray Computer Assisted Tomography, Tomodensitometry, Pulmonary Thromboembolisms, X-Ray Computerized Axial Tomography, Computed Tomography, X-Ray, X-Ray Tomography, Computed, Embolism, Pulmonary, Tomography, Xray Computed, CT X Ray, Thromboembolism, Pulmonary
- Subject:
- Lung Diseases, Pulmonary Embolism, Tomography, X-Ray Computed, Diagnostic Techniques and Procedures, Infarction, Pathological Conditions, Signs and Symptoms, Pathologic Processes, Respiratory Tract Diseases, Multimodal Imaging, Diagnostic Imaging, Ischemia
- Creator:
- i-Human Patients, Inc., Inc.
- Publisher:
- i-Human Patients, Inc., Inc.
- Language:
- English
- Copyright Holder:
- i-Human Patients, Inc.
- Rights:
- http://www.i-human.com/service-agreement-print
- Resource Type:
- Medical Imaging
- Identifier:
- 1429
- Title:
- CT (chest), (axial), Pulmonary Embolism
- Description:
- CT Chest - Pulmonary embolism
- Keyword:
- Computerized Tomography, X-Ray, Electron Beam Tomography, Computed Tomography, X-Ray, X Ray Tomography, Computed, Tomography, Transmission Computed, Embolism, Pulmonary, Tomography, X Ray Computed, CAT Scan, X-Ray, Computerized Tomography, X Ray, Thromboembolisms, Pulmonary, CT Scan, X-Ray, Pulmonary Embolisms, Tomography, X-Ray Computerized Axial, CT X Ray, Infarct, X-Ray Computer Assisted Tomography, Tomodensitometry, Embolisms, Pulmonary, Diagnosis, X-Ray Tomography, Computed, X Ray Computerized Tomography, Pulmonary Thromboembolisms, Thromboembolism, Pulmonary, Tomography, X-Ray Computer Assisted, Cine-CT, Tomography, Xray Computed, Tomography, X-Ray Computerized, X-Ray Computerized Axial Tomography, Computed X Ray Tomography, Pulmonary Thromboembolism, CAT Scan, X Ray, Electron Beam Computed Tomography
- Subject:
- Lung Diseases, Diagnostic Techniques and Procedures, Tomography, X-Ray Computed, Diagnostic Imaging, Pulmonary Embolism, Respiratory Tract Diseases, Multimodal Imaging
- Creator:
- i-Human Patients, Inc., Inc.
- Publisher:
- i-Human Patients, Inc., Inc.
- Language:
- English
- Copyright Holder:
- i-Human Patients, Inc.
- Rights:
- http://www.i-human.com/service-agreement-print
- Resource Type:
- Medical Imaging
- Identifier:
- 1431
- Title:
- CT (chest), Pulmonary Embolism with Infarction, Superior to Inferior
- Description:
- CT Chest - Pulmonary embolism with infarct superior to inferior
- Keyword:
- CAT Scan, X-Ray, Tomography, X-Ray Computerized, Electron Beam Computed Tomography, Tomography, X-Ray Computer Assisted, X-Ray Computer Assisted Tomography, X-Ray Computerized Axial Tomography, X-Ray Tomography, Computed, CAT Scan, X Ray, CT X Ray, Pulmonary Thromboembolism, X Ray Tomography, Computed, Pulmonary Embolisms, Embolism, Pulmonary, Pulmonary Thromboembolisms, Tomography, X-Ray Computerized Axial, Tomography, Transmission Computed, Computerized Tomography, X Ray, Infarct, Tomography, X Ray Computed, Embolisms, Pulmonary, Cine-CT, X Ray Computerized Tomography, Thromboembolisms, Pulmonary, CT Scan, X-Ray, Computerized Tomography, X-Ray, Diagnosis, Computed X Ray Tomography, Tomography, Xray Computed, Thromboembolism, Pulmonary, Electron Beam Tomography, Computed Tomography, X-Ray, Tomodensitometry
- Subject:
- Ischemia, Diagnostic Imaging, Infarction, Diagnostic Techniques and Procedures, Pathological Conditions, Signs and Symptoms, Pathologic Processes, Tomography, X-Ray Computed, Multimodal Imaging
- Creator:
- i-Human Patients, Inc., Inc.
- Publisher:
- i-Human Patients, Inc., Inc.
- Language:
- English
- Copyright Holder:
- i-Human Patients, Inc.
- Rights:
- http://www.i-human.com/service-agreement-print
- Resource Type:
- Medical Imaging
- Identifier:
- 1428
- Title:
- CT (chest), Right Heart Hypertrophy (annotated)
- Description:
- CT - Chest - right heart hypertrophy with and without labels
- Keyword:
- Tomography, X-Ray Computer Assisted, Hypertrophy, Tomography, Xray Computed, X-Ray Computer Assisted Tomography, CT X Ray, CAT Scan, X Ray, Electron Beam Computed Tomography, Tomography, X-Ray Computerized, Tomography, X-Ray Computerized Axial, Electron Beam Tomography, Cine-CT, Heart, Tomography, Transmission Computed, Tomodensitometry, Computerized Tomography, X Ray, Diagnosis, CAT Scan, X-Ray, CT Scan, X-Ray, X Ray Tomography, Computed, Computed X Ray Tomography, X-Ray Computerized Axial Tomography, Computed Tomography, X-Ray, Tomography, X Ray Computed, Computerized Tomography, X-Ray, X-Ray Tomography, Computed, X Ray Computerized Tomography, Right Heart Hypertrophy
- Subject:
- Hypertrophy, Pathological Conditions, Signs and Symptoms, Diagnostic Imaging, Pathological Conditions, Anatomical, Cardiomegaly, Diagnostic Techniques and Procedures, Multimodal Imaging, Tomography, X-Ray Computed
- Creator:
- Chris DeMauro, MD
- Publisher:
- i-Human Patients, Inc., Inc.
- Language:
- English
- Copyright Holder:
- Chris DeMauro, MD
- Rights:
- http://www.i-human.com/service-agreement-print
- Resource Type:
- Medical Imaging
- Identifier:
- 1340
- Title:
- CT (abdomen), Hemoperitoneum
- Description:
- Emphysema with no infiltrate or pneumothorax. The visualized portion of the heart is normal in size. There are no pleural or pericardial effusions. There are coronary artery calcifications. There is active arterial extravasation from a peripheral liver mass at the dome of the liver, which measures approximately 3.8 x 3.2 cm. This mass enhances centrally and peripherally during the arterial phase of this examination. There is extensive hemoperitoneum, in varying stages of density. When compared with the prior CT scan, there was a lesion within the liver which demonstrated early arterial . The liver contour is smooth. There is a second less well-defined area of increased enhancement (series 2 image 81) of uncertain etiology. There are 2 hypodensities in the right hepatic lobe which are too small to characterize. There are small periportal and paraaortic lymph nodes. The spleen and pancreas are normal in appearance. The adrenal glands are unremarkable. There are multiple radiopaque gallstones. The kidneys enhance normally and symmetrically. There is a 2.1 cm renal cyst within the left interpolar region. There are multiple other renal hypodensities which are too small to characterize, however probably represents cysts. There is no hydronephrosis. The bowel is normal in caliber without evidence of bowel wall thickening. There are scattered colonic diverticula. The aorta and its visceral branches are patent. There are postsurgical changes from recent aortobifemoral graft placement with patency of the graft. The pelvic viscera are unremarkable. There are no fractures. There are mild degenerative changes of the spine. IMPRESSION: Active extravasation with extensive hemoperitoneum arising from a 3.8 cm peripherally enhancing lesion within the dome of the liver.
- Keyword:
- Tomography, X-Ray Computerized Axial, CAT Scan, X-Ray, Diagnosis, CAT Scan, X Ray, Computerized Tomography, X Ray, Tomography, X-Ray Computerized, Computed X Ray Tomography, Electron Beam Tomography, X Ray Tomography, Computed, CT Scan, X-Ray, X Ray Computerized Tomography, Tomography, X-Ray Computer Assisted, X-Ray Computer Assisted Tomography, Tomography, Transmission Computed, Computerized Tomography, X-Ray, X-Ray Tomography, Computed, Tomodensitometry, Tomography, X Ray Computed, air in lungs, Computed Tomography, X-Ray, CT X Ray, Cine-CT, Electron Beam Computed Tomography, Tomography, Xray Computed, X-Ray Computerized Axial Tomography
- Subject:
- Tomography, X-Ray Computed, Pathological Conditions, Signs and Symptoms, Multimodal Imaging, Diagnostic Techniques and Procedures, Pathologic Processes, Emphysema, Diagnostic Imaging
- Creator:
- Chris DeMauro, MD
- Publisher:
- i-Human Patients, Inc., Inc.
- Language:
- English
- Copyright Holder:
- Chris DeMauro, MD
- Rights:
- http://www.i-human.com/service-agreement-print
- Resource Type:
- Medical Imaging
- Identifier:
- 1333
- Title:
- CT (abdomen), (coronal), Hemoperitoneum
- Description:
- Emphysema with no infiltrate or pneumothorax. The visualized portion of the heart is normal in size. There are no pleural or pericardial effusions. There are coronary artery calcifications. There is active arterial extravasation from a peripheral liver mass at the dome of the liver, which measures approximately 3.8 x 3.2 cm. This mass enhances centrally and peripherally during the arterial phase of this examination. There is extensive hemoperitoneum, in varying stages of density. When compared with the prior CT scan, there was a lesion within the liver which demonstrated early arterial . The liver contour is smooth. There is a second less well-defined area of increased enhancement (series 2 image 81) of uncertain etiology. There are 2 hypodensities in the right hepatic lobe which are too small to characterize. There are small periportal and paraaortic lymph nodes. The spleen and pancreas are normal in appearance. The adrenal glands are unremarkable. There are multiple radiopaque gallstones. The kidneys enhance normally and symmetrically. There is a 2.1 cm renal cyst within the left interpolar region. There are multiple other renal hypodensities which are too small to characterize, however probably represents cysts. There is no hydronephrosis. The bowel is normal in caliber without evidence of bowel wall thickening. There are scattered colonic diverticula. The aorta and its visceral branches are patent. There are postsurgical changes from recent aortobifemoral graft placement with patency of the graft. The pelvic viscera are unremarkable. There are no fractures. There are mild degenerative changes of the spine. IMPRESSION: Active extravasation with extensive hemoperitoneum arising from a 3.8 cm peripherally enhancing lesion within the dome of the liver.
- Keyword:
- X-Ray Computerized Axial Tomography, Electron Beam Tomography, Tomography, X-Ray Computerized, Tomodensitometry, Tomography, Transmission Computed, CAT Scan, X-Ray, Cine-CT, Computed Tomography, X-Ray, Electron Beam Computed Tomography, Tomography, Xray Computed, Diagnosis, X Ray Tomography, Computed, X-Ray Tomography, Computed, CAT Scan, X Ray, X-Ray Computer Assisted Tomography, CT X Ray, X Ray Computerized Tomography, Tomography, X-Ray Computerized Axial, Tomography, X Ray Computed, air in lungs, Tomography, X-Ray Computer Assisted, Computerized Tomography, X Ray, Computed X Ray Tomography, Computerized Tomography, X-Ray, CT Scan, X-Ray, CT Scan, Coronal Plane
- Subject:
- Diagnostic Techniques and Procedures, Diagnostic Imaging, Multimodal Imaging, Tomography, X-Ray Computed, Emphysema, Pathological Conditions, Signs and Symptoms, Pathologic Processes
- Creator:
- Chris DeMauro, MD
- Publisher:
- i-Human Patients, Inc., Inc.
- Language:
- English
- Copyright Holder:
- Chris DeMauro, MD
- Rights:
- http://www.i-human.com/service-agreement-print
- Resource Type:
- Medical Imaging
- Identifier:
- 1333
- Title:
- CT (chest), (axial), Adult Male Pulmonary Embolism with Right Heart Strain
- Description:
- There are occlusive pulmonary emboli within the left and right main pulmonary arteries. The thrombus within the right main pulmonary artery extends into the right lower lobe segmental arteries. The heart is slightly enlarged with enlargement of the ventricle deviating the intraventricular septum indicating right heart strain. Additionally the main pulmonary artery measures approximately 3.2 cm in diameter indicating pulmonary arterial hypertension. Lung windows demonstrates patchy consolidation at the right lower lobe peripherally which represents infarcted lung parenchyma. There is a small right-sided pleural effusion. The left lung is clear. There is no evidence of enlarged hilar or mediastinal lymphadenopathy. The visualized portions of the upper abdominal viscera including the adrenal glands are normal. Evaluation of bone windows demonstrate no abnormality. IMPRESSION: Bilateral central pulmonary emboli with left lower lobe pneumonia infarction.
- Keyword:
- Pulmonary, X Ray Tomography, Computed, CAT Scan, X-Ray, Tomography, X Ray Computed, X-Ray Computerized Axial Tomography, Tomography, X-Ray Computerized, Tomography, X-Ray Computer Assisted, Tomography, X-Ray Computerized Axial, Tomography, Xray Computed, Computed Tomography, X-Ray, Tomodensitometry, Cine-CT, X-Ray Tomography, Computed, CT X Ray, Pulmonary Embolism, X-Ray Computer Assisted Tomography, Computerized Tomography, X-Ray, X Ray Computerized Tomography, Electron Beam Computed Tomography, CT Scan, X-Ray, Thromboembolism, Computerized Tomography, X Ray, Tomography, Transmission Computed, Respiratory Tract Diseases, Diagnosis, Lung Diseases, Embolism, CAT Scan, X Ray, Computed X Ray Tomography, Electron Beam Tomography, CT Scan, Axial Plane
- Subject:
- Pulmonary Embolism, Lung Diseases, Respiratory Tract Diseases, Multimodal Imaging, Diagnostic Techniques and Procedures, Diagnostic Imaging, Tomography, X-Ray Computed
- Creator:
- Chris DeMauro, MD
- Publisher:
- i-Human Patients, Inc., Inc.
- Language:
- English
- Copyright Holder:
- Chris DeMauro, MD
- Rights:
- http://www.i-human.com/service-agreement-print
- Resource Type:
- Medical Imaging
- Identifier:
- 1336